Checking Connections - Sony StorStation FSV-VN5 Administrator's Manual

Hybrid network filesaver
Table of Contents

Advertisement

Checking Connections

Main server
Cache server
AIT library
Before turning on the power verify that the system is connected properly.
Connect the system according to the diagram below.
User LAN
Not used
SCSI cable
Terminator
Notes
• When connecting more than one AIT library, remove the SCSI bus terminator
plugged into the first AIT library and connect the second AIT library to the
open port with a SCSI cable.
• An active terminator must be connected to the last AIT library on the SCSI
bus, as shown in the diagram.
• Use the following table to set up the SCSI ID of each library.
AIT library
TL1 (first unit)
00
TL2 (second unit)
03
TL3 (third unit)
06
TL4 (fourth unit)
10
Caution
Assign the SCSI IDs in order, starting from a lower number, so that the display
of the management software matches the AIT library. Do not use ID 7 as it is
already used by the main server.
Network cable
Not used
Switching hub
Network cable
Not used
Mounted drive 1
01
04
08
11
Mounted drive 2
02
05
09
12
8
Chapter 2 Preparations

Advertisement

Table of Contents
loading

Table of Contents