Checking File Systems (Fsck); Specifications; Srpc-5 - Sony SRPC-5 Operation Manual

Memory data transfer unit
Hide thumbs Also See for SRPC-5:
Table of Contents

Advertisement

The tasks that can be defined in a job file correspond with
most of the items that can be specified in the menus of the
web application.
For details, see "Job File Samples" on page 41 in
"Appendix".

Checking File Systems (FSCK)

The file system of an HDD connected to the unit by
eSATA can be checked and restored by following the
below steps.
Note
The HFS+ file system is the only HDD format that can be
checked and restored.
1
Click the DIAGNOSIS menu button in the web
application screen, and then click the OTHERS tab.
The OTHERS tab screen appears.
2
Select the node to perform the file check from
"NODE" in the FSCK (HFS) field, and then click the
EXEC button.
When the file check is complete, a results screen like
the one below appears.
36

Specifications

Specifications
Notes
• Always make a test recording, and verify that it was
recorded successfully.
SONY WILL NOT BE LIABLE FOR DAMAGES OF
ANY KIND INCLUDING, BUT NOT LIMITED TO,
COMPENSATION OR REIMBURSEMENT ON
ACCOUNT OF FAILURE OF THIS UNIT OR ITS
RECORDING MEDIA, EXTERNAL STORAGE
SYSTEMS OR ANY OTHER MEDIA OR
STORAGE SYSTEMS TO RECORD CONTENT OF
ANY TYPE.
• Always verify that the unit is operating properly before
use. SONY WILL NOT BE LIABLE FOR
DAMAGES OF ANY KIND INCLUDING, BUT
NOT LIMITED TO, COMPENSATION OR
REIMBURSEMENT ON ACCOUNT OF THE LOSS
OF PRESENT OR PROSPECTIVE PROFITS DUE
TO FAILURE OF THIS UNIT, EITHER DURING
THE WARRANTY PERIOD OR AFTER
EXPIRATION OF THE WARRANTY, OR FOR
ANY OTHER REASON WHATSOEVER.

SRPC-5

General
Power supply
100 to 240 V AC (50/60 Hz)
Power consumption
110 W (with all options installed)
Inrush current
(1) Maximum possible inrush current at
initial switch-on (Voltage changes
caused by manual switching):
28 A peak, 1.7 A r.m.s. (240 V AC)
(2) Inrush current after a mains
interruption of five seconds (Voltage
changes caused at zero-crossing):
5 A peak, 1.6 A r.m.s. (240 V AC)
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Mass
10 kg (22 lb.)
Dimensions
427 × 43.6 × 546 mm (16
1
21
/
in.) (W×H×D)
2
Input connectors
AUX INPUT
A/B: BNC (2)
HD SDI (1.485 Gbps) (conforming to
SMPTE-292M/372M, BTA-S004B)
3G SDI (2.97 Gbps) (SMPTE-424M)
7
3
/
× 1
/
×
8
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr-pc4