Connect Power; Lubrication System Setup - Graco Reactor 2 H-30 Operation

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Setup

Connect Power

Power
Connect
Connect
Power
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
1. Turn main power switch (MP) OFF.
2. Open electrical enclosure door.
NOTE: Terminal jumpers are located inside the
NOTE:
NOTE:
electrical enclosure door if equipped.
3. Install supplied terminal jumpers in the positions
shown in image for the power source used (H-30
and H-XP2 models only).
4. Route power cable through strain relief (EC) in
electrical enclosure.
5. Connect incoming power wires as shown in
image. Gently pull on all connections to verify
they are properly secured.
6. Verify all items are connected properly as shown
in image then close electrical enclosure door.
See
Models, page 9
requirements.
NOTE:
NOTE:
NOTE: 350–415 VAC systems are not designed to
operate from 480 VAC power source.
32
for Reactor power
Lubrication System
Lubrication
Lubrication
Component A A A (ISO)
Component
Component
(LR) with Graco Throat Seal Liquid (TSL), part
206995 (supplied).
1. Lift the lubricant reservoir (LR) out of the bracket
(RB) and remove the container from the cap.
2. Fill with fresh lubricant. Thread the reservoir onto
the cap assembly and place it in the bracket (RB).
3. Push the larger diameter supply tube (ST)
approximately 1/3 of the way into the reservoir.
4. Push the smaller diameter return tube (RT) into
the reservoir until it reaches the bottom.
NOTE:
NOTE: The return (RT) must reach the bottom of
NOTE:
the reservoir to ensure that isocyanate crystals
will settle to the bottom and not be siphoned into
the supply tube (ST) and returned to the pump.
5. The lubrication is ready for operation. No priming
is required.
ti26342a_17D775
System Setup
Setup
System
Setup
(ISO) Pump:
(ISO)
Pump: Fill ISO lube reservoir
Pump:
334945J