Install Fluid
Fluid Temperature
Temperature Sensor
Install
Install
Fluid
Temperature
The Fluid Temperature Sensor (FTS) is supplied.
Install FTS between main hose and whip hose (see
your heated hose manual).
Connect Heated
Heated Hose
Connect
Connect
Heated
NOTICE
NOTICE
NOTICE
To avoid damage to the hose, only connect Reactor
2 proportioners to genuine Graco heated hoses.
Refer to your heated hose manual for detailed
connection instructions.
1. Turn off main power switch (MP).
2. Remove cover (CV).
334945J
Sensor
Sensor
Hose to to to Proportioner
Proportioner
Hose
Proportioner
3. For proportioners with electrical splice connectors
(S):
a. Connect hose power wires to electrical splice
connectors (S) from proportioner. Wrap
connectors with electrical tape.
4. Route heated hose wires (HW) through strain
relief (SR) and install wires into the open screw
terminals on the terminal block (TB). Torque to
35 in-lb (3.95 N•m).
5. Reinstall cover (CV).
Setup
33