Usb Data; Download Procedure; Usb Logs - Graco Reactor 2 H-30 Operation

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

USB Data

Data
USB
USB
Data

Download Procedure

Procedure
Download
Download
Procedure
NOTE: If log files are not correctly saving to the USB
NOTE:
NOTE:
flash drive (for example, missing or empty log files),
save desired data off of the USB flash drive and
reformat it before repeating the download procedure.
NOTE:
NOTE: System configuration setting files and custom
NOTE:
language files can be modified if the files are in the
UPLOAD folder of the USB flash drive. See System
Configuration Settings File, Custom Language File,
and Upload Procedure sections.
1. Insert USB flash drive into USB port.
2. The menu bar and USB indicator lights indicate
that the USB is downloading files. Wait for USB
activity to complete.
3. Remove USB flash drive from USB port.
4. Insert USB flash drive into USB port of computer.
5. The USB flash drive window automatically opens.
If it does not, open USB flash drive from within
Windows® Explorer.
6. Open GRACO folder.
7. Open the system folder. If downloading data
from more than one system, there will be more
than one folder. Each folder is labeled with the
corresponding serial number of the ADM (The
serial number is on the back of the ADM.)
8. Open DOWNLOAD folder.
9. Open DATAxxxx folder labeled with the highest
number. The highest number indicates the most
recent data download.
10. Open log file. Log files open in Microsoft® Excel
by default as long as the program is installed.
However, they can also be opened in any text
editor or Microsoft® Word.
NOTE: All USB logs are saved in Unicode
NOTE:
NOTE:
(UTF-16) format. If opening the log file in
Microsoft Word, select Unicode encoding.
334945J

USB Logs

Logs
USB
USB
Logs
NOTE: The ADM can read/write to FAT (File
NOTE:
NOTE:
Allocation Table) storage devices. NTFS, used by 32
GB or greater storage devices, is not supported.
During operation, the ADM stores system and
performance related information to memory in the
form of log files. The ADM maintains six log files:
• Event Log
• Job Log
• Daily Log
• System Software Log
• Blackbox Log
• Diagnostics Log
Follow
Download Procedure, page
log files.
Each time a USB flash drive is inserted into the ADM
USB port, a new folder named DATAxxxx is created.
The number at the end of the folder name increases
each time a USB flash drive is inserted and data is
downloaded or uploaded.
Event Log
Event
Event
Log
Log
The event log file name is 1–EVENT.CSV and is
stored in the DATAxxxx folder.
The event log maintains a record of the last 49,000
events and errors. Each event record contains:
• Date of event code
• Time of event code
• Event code
• Event type
• Action taken
• Event Description
Event codes include both error codes (alarms,
deviations, and advisories) and record only events.
Actions Taken includes setting and clearing event
conditions by the system, and acknowledging error
conditions by the user.
USB Data
69, to retrieve
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reactor 2 h-30 eliteReactor 2 h-40Reactor 2 h-40 eliteReactor 2 h-50Reactor 2 h-50 eliteReactor 2 h-xp2 ... Show all

Table of Contents