Enable Hose Resistance Mode; Disable Hose Resistance Mode - Graco Reactor 2 H-30 Operation

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Enable Hose
Hose Resistance
Resistance Mode
Enable
Enable
Hose
Resistance
This mode requires a calibration factor to run (see
Calibration Procedure, page
1. Enter Setup Mode and navigate to System
screen 3.
2. Select Resistance from the drop-down menu.
NOTE: If no calibration factor is shown, follow the
NOTE:
NOTE:
Calibration Procedure, page
NOTICE
NOTICE
NOTICE
To prevent damage to the heated hose, a hose
calibration is required if any of the following
conditions are true:
• The hose has never been calibrated before.
• A section of hose has been replaced.
• A section of hose has been added.
• A section of hose has been removed.
3. Enter Run Mode and navigate to the Targets
screen. Use the up and down arrows to set the
desired temperature.
334945J
Mode
Mode
57).
57.
NOTE: Hose Resistance Mode controls the
NOTE:
NOTE:
average fluid temperature of the A and B fluid.
Set the hose temperature set point halfway
between the A and B temperature set points
and adjust as needed to achieve desired
performance.
4. Navigate back to the Run Mode home screen.
The Hose Resistance Mode icon will display.
NOTE:
NOTE: When Hose Resistance Mode is enabled
NOTE:
and the hose heat is off, the hose temperature
will display "- - -". In Hose Resistance Mode,
temperature values are only displayed when the
heat is on.
Disable Hose
Hose Resistance
Resistance Mode
Disable
Disable
Hose
Resistance
1. Enter Setup mode.
2. Navigate to System screen 3.
3. Set the Hose Control Mode to FTS.
Spraying
Mode
Mode
55