Purge Air Procedure - Graco Reactor 2 H-30 Operation

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Spraying
Purge Air
Air Procedure
Procedure
Purge
Purge
Air
Procedure
NOTE:
NOTE: Perform this procedure any time air is
NOTE:
introduced into the system.
1. Relieve pressure.
Pressure Relief Procedure, page
2. Install a recirculation kit or install bleed lines
between the outlet manifold recirculation fitting
and a waste container.
NOTICE
NOTICE
NOTICE
To prevent equipment damage, do not circulate
fluid containing a blowing agent without
consulting with your material supplier regarding
fluid temperature limits.
3. Press the proportioner stop button
off the motor.
4. To relieve air pressure from the feed pumps,
disconnect the air supply lines (G) from the feed
pumps (K).
60
See
62.
to turn
5. Set the PRESSURE RELIEF/SPRAY valves
(SA, SB) to PRESSURE RELIEF/CIRCULATION
.
6. Adjust the pressure in the feed pump air supply
lines to 100 psi.
7. To pressurize the feed pumps, connect the air
supply lines (G) to the feed pumps (K).
8. Adjust the proportioner pressure compensator
knob to less than 500 psi (3.4 MPa, 34 Bar).
9. Press the proportioner start button
the motor. Run 1 gallon (3.8 L) of material
through the system.
10. Set the PRESSURE RELIEF/SPRAY valves (SA,
SB) to SPRAY
to start
.
334945J