Enable Hose Manual Mode; Disable Hose Manual Mode - Graco Reactor 2 H-30 Operation

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Spraying
Enable Hose
Hose Manual
Manual Mode
Enable
Enable
Hose
Manual
1. Enter Setup Mode and navigate to System
screen 3.
2. Set the Hose Control Mode to Manual.
NOTE: When manual hose mode is enabled, the
NOTE:
NOTE:
manual hose mode advisory EVCH-V will appear.
3. Enter Run Mode and navigate to the Targets
screen. Use the up and down arrows to set the
desired hose current.
56
Mode
Mode
Hose Current
Current Settings
Settings Hose
Hose
Hose
Current
Settings
Default
Maximum
4. Navigate back to the Run Mode Home screen.
The hose now displays a current instead of a
temperature.
NOTE: Until the RTD sensor is repaired, the
NOTE:
NOTE:
T6DH sensor error alarm will display each time
the system is powered up.
Disable Hose
Disable
Disable
Hose Manual
Hose
Manual Mode
Manual
1. Enter Setup Mode.
2. Navigate to System screen 3.
3. Set the Hose Control Mode to FTS or Resistance.
Hose Current
Current
Hose
Current
20A
37A
Mode
Mode
334945J