Maintenance

Maintenance
Maintenance
Maintenance
Prior to performing any maintenance procedures,
follow
Pressure Relief Procedure, page
Preventative Maintenance
Maintenance Schedule
Preventative
Preventative
Maintenance
The operating conditions of your particular system
determine how often maintenance is required.
Establish a preventive maintenance schedule by
recording when and what kind of maintenance is
needed, and then determine a regular schedule for
checking your system.
• Inspect hydraulic and fluid lines for leaks daily.
• Clean up all hydraulic leaks; identify and repair the
cause of the leak.
• Inspect fluid inlet strainer screens daily. See below.
• Keep component A from exposure to moisture to
prevent crystallization.
• Check hydraulic fluid level weekly. Check
hydraulic fluid level on a dipstick. Fluid level
must be between indent marks on dipstick.
Refill as required with approved hydraulic fluid,
Technical Specifications
Specifications and the Approved
see Technical
Technical
Specifications
Anti-Wear (AW) Hydraulic Oils table in the Reactor
Repair-Parts manual 334946. If fluid is dark in
color, change fluid and filter.
• Change break-in oil in a new unit after the first 250
hours of operation or within 3 months, whichever
comes first. See the table below for recommended
frequency of oil changes.
64
Table 5 5 5 Frequency
Table
Table
Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
0° to 90° F
(-17° to 32° C)
62.
90° F and above
(32° C and above)
Schedule
Schedule
Proportioner

Proportioner Maintenance

Proportioner
Fluid Inlet
Fluid
Fluid
Inspect fluid inlet strainer screens daily, see
Fluid Inlet Strainer Screens, page
Grease Circulation
Grease
Grease
Grease circulation valves (SA and SB) with Fusion
grease (117773) weekly.
ISO Lubricant
ISO
ISO
Inspect ISO lubricant level and condition
daily. Refill or replace as needed. See
Pump Lubrication System, page
Moisture
Moisture
Moisture
To prevent crystallization, do not expose component
A to moisture in air.
Gun Mix
Gun
Gun
Clean gun mix chamber ports regularly. See gun
manual.
Frequency of of of Oil
Oil Changes
Changes
Frequency
Oil
Changes
Recommended
Recommended
Recommended
Frequency
Frequency
Frequency
1000 hours or 12 months,
whichever comes first
500 hours or 6 months,
whichever comes first
Maintenance
Maintenance
Inlet Strainer
Strainer Screens
Screens
Inlet
Strainer
Screens
Circulation Valves
Valves
Circulation
Valves
Lubricant Level
Level
Lubricant
Level
Mix Chamber
Chamber Ports
Ports
Mix
Chamber
Ports
64.
66.
334945J

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reactor 2 h-30 eliteReactor 2 h-40Reactor 2 h-40 eliteReactor 2 h-50Reactor 2 h-50 eliteReactor 2 h-xp2 ... Show all

Table of Contents