Group 21
Transmission housing
NOTE! The transmission cover and starter motor can
be installed together.
20. Apply silicon sealing compound (1161231-4) as
shown in the diagram to the sealing surface for
the transmission housing.
Lightly oil the crankshaft seal.
21. Fit the transmission cover, without tightening the
screws.
NOTE! Line it up with the oil sump sealing sur-
face.
22. Tighten the screws to ......................... 21 ±2 Nm
(15 ±1.5 lbf ft).
Oil pump/cover
23. Lightly oil the oil pump rotor.
Assembly, complete engine