Gps time & frequency standard
Table of Contents

Advertisement

Fiber Optic Output Module (4372A)
Characteristic
Number of outputs
Output connectors
AC Power Supply (4385A)
100–240 V AC, 50-60 Hz, ~.75A
Power Mains Fuse AC Input: Two 250 V~1 A T (Time delay) 5 x 20 mm
DC Power Supply (4886A)
–48 VDC (SELV type), Power Inlet Type, DC input Mates with 3 pin Amp Part#: 1-350346-0
connector with female sockets Amp Part# 925661-1
Power Supply Cord Set, DC input Minimum 1.5 mm² (14 AWG) with a 15A fuse or circuit
breaker. A 20A circuit breaker may be used if the external wiring is jacketed 14 AWG, with
maximum length of 20 feet.
DC Input: Two 250 V~1.6 A T (Time delay) 5 x 20 mm
Power Consumption: 52W (fully loaded chassis).
Four
LC – Duplex in SFP pluggable modules. These modules can be
individually changed to different mode transceivers.
Outputs contain time code, 1 PPS and frequency for ATS 6511
Inputs are not required and contain status information from the ATS
6511 connected directly to the output, or from multiple ATS 6511s
connected to a TSC-4340A connected to this output
70
DOC06501_Revision F
ATS-6501 Users Guide
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ats-6501 t-flex

Table of Contents