Internal Clocks; External Reference - Symmetricom ATS-6501 Tflex User Manual

Gps time & frequency standard
Table of Contents

Advertisement

o GPS Tracking indicator is RED or OFF. Enter the correct position for the
antenna. Use the status health:gps_error command to look at the status of the
GPS hardware.

6.2.4 Internal Clocks

If you suspect there may be an issue with the internal clocks use the status health and
status oscillator commands to look at the status of the internal clocks.
Note: The example below has been edited to show the relevant fields in the system health status
for the clocks.
ATS-6501>status health
[clock_freq_step]
[active] false
[occurrences] 0
[clock_phase_step]
[active] false
[occurrences] 0
[clock_steer]
[active] false
[occurrences] 0
[clock_wander]
[active] false
[occurrences] 0
ATS-6501>status oscillator
[external] locked
[internal] locked
[lns] locked
[locked] true
Users can also check the status of the time scale to ensure the UTC offset value [ptd] is
under +/- 100nSec from UTC and the clock is being steered
ATS-6501>status kas2
[antenna_delay] -1.878000000000000e-08
[frequency] -5.116576335241098e+01
[frequency_aging] -1.726953124522067e-06
[phase_error] 6.369868716533948e-09
[ptd] -2.7412538500000002e-09
[steer] -3.2777525484561920e-11

6.2.5 External Reference

If you suspect there may be issues with the external reference use the status health and
status oscillator commands to look at the status of the external reference and internal clocks.
Note: The example below has been edited to show the relevant fields in the system health status
for the clocks.
ATS-6501>status health
59
DOC06501_Revision F
ATS-6501 Users Guide