[over_temperature]
[active] false
[occurrences] 0
[power_supply]
[1]
[active] false
[occurrences] 0
[2]
[active] false
[occurrences] 0
I.
The [ref_unlocked] fields are reporting the clock status and system performance
information. The reference should be locked ([ref_unlocked] [active] = false).
[ref_unlocked]
[active] false
[occurrences] 0
J. Once the system obtains a sufficient amount of clock data the kas2 values will be
available.
[kas2]
[antenna_delay] -1.878000000000000e-08
[frequency] -5.116576335241098e+01
[frequency_aging] -1.726953124522067e-06
[phase_error] 6.369868716533948e-09
[ptd] 5.814561427000000e-09
[steer] -5.411878228187561e-11
K. The system should show that NTP is locked (true) and that the system is using the
internal clock (REFCLK(25,0)
[ntp]
[locked] true
[source] REFCLK(25,0)
L. The system will also show if the external & internal clocks have been detected, the
outputs should be enabled and the system will provide the internal operating temperature.
If an external 10MHz signal is not being provided, the oscillator:external field will
display signal missing
[oscillator]
[external] unknown (reference_type=Cesium)
[internal] locked
[lns] locked
[locked] true
[outputs] enabled
[temperature] 27
M. The last set of data [tflex] will display the system network information, serial number, the
startup time (when NTP Locked), the uptime since the last power cycle, the software
version running on the system, and the time the status command was executed.
[network]
[MAC] 00:30:96:00:00:98