20. Image quality problems

20.1 Printer system

NOTE
• Typical faulty image samples shown in the following are all printed with A4S set-
ting.
20.1.1

White lines/bands, colored lines/bands in sub scan direction

A. Typical faulty images
white lines in
sub scan direction
B. Troubleshooting procedure
Step
Section
1
2
3
Imaging
cartridge
4
5
6
PH unit
7
2nd transfer
8
roller
9
Media path
10
Fuser unit
11
white bands in
sub scan direction
Check item
Are there scratches or lines evi-
dent on the photo conductor sur-
face?
Is the outside dirty?
Is the connector or contact termi-
nal of the imaging cartridge con-
nected properly?
Is the transfer belt dirty with fin-
gerprints or oil?
Is the transfer belt dirty or
scratched?
Is the connector or contact termi-
nal of the PH unit connected
properly?
Is the window surface dirty?
Is the 2nd transfer roller dirty or
scratched?
Is there a foreign object in the
media path?
Is the fusing entrance guide plate
dirty or scratched?
Have steps 1 to10 eliminated the
problem?
http://www.manuals4you.com
20. Image quality problems
colored lines in
colored bands in
sub scan direction
sub scan direction
Result
YES
Replace the imaging cartridge.
YES
Clean.
NO
Clean the contact terminal.
YES
Clean.
Wipe the surface clean of dirt with
a soft cloth.
YES
Replace the scratched transfer
belt with a new imaging cartridge.
Clean the contact terminal or
NO
reconnect the connector.
YES
Clean.
YES
Replace the 2nd transfer roller.
YES
Remove the foreign object.
Clean.
YES
Replace the fuser unit.
Replace the toner cartridge.
NO
→ Replace the PH unit.
A0CRF4C503DA