Field Service Ver. 1.0 Nov. 2008
7.3.14

Fuser unit

• The temperature gets high in the vicinity of the fuser unit. You may get
burned when you come into contact with the area. Before replacement
operations, make sure that more than 20 minutes have elapsed since the
main and sub power switches were turned off.
1. Turn OFF the power switch, unplug the power cord from the power outlet, and let the
machine to stand idle for about 20 min.
[1]
[1]
4. To reinstall, reverse the order of removal.
NOTE
• When the fuser unit is replaced with a new one, it is necessary to reset the mainte-
nance counter.
See P.138
CAUTION
A0HFF2C506DA
[2]
A0HFF2C510DA
http://www.manuals4you.com
2. Open the top cover [1].
NOTE
• The left picture shows magicolor
1690MF.
3. Pull up the lever [1] to remove the
fuser unit [2].