Field Service Ver. 1.0 Nov. 2008
3.3

Maintenance Procedure (periodical check parts)

3.3.1

Toner cartridge (C/M/Y/K)

A. Periodically replaced parts/cycle
• Standard in-box toner cartridge (C, M, Y): Every 500 prints
• Standard in-box toner cartridge (K): Every 1,000 prints
• Standard-capacity toner cartridge (C,M,Y): Every 1,500 prints
• High-capacity toner cartridge (C,M,Y,K): Every 2,500 prints
B. Removal procedure
1. Check the color of the toner cartridge to be replaced on the control panel.
2. Select [PRINTER MODE] - [T/C CHANGE] - [REPLACE MODE] from the menu and
select the toner cartridge of the specific color of toner to be replaced.
See P.74
[1]
[2]
A0HFF2C502DA
[1]
A0HFF2C503DA
http://www.manuals4you.com
3. Periodical check
3. Open the front cover [1] and make
sure that the specific toner cartridge
to be replaced is in the front.
4. Hold onto the handle [1] of the toner
cartridge, pull it and remove the
toner cartridge [2].
NOTE
• When all toner cartridges need to
be removed and replaced manually,
select [PRINTER MODE] - [T/C
CHANGE] - [EJECT MODE].
See P.75