14. SERVICE MODE
14.4.14

TEMPERATURE

• To adjust the fusing heating temperature individually for each paper type so as to
Function
ensure good fusing performance that varies with varying environmental conditions.
Use
• When fusing performance is poor, or wax streak or offset occurs when the type of
paper is changed or environmental conditions change.
• Use this function when curled paper, or paper misfeed as a result of the curled paper,
occurs under varying environmental conditions or depending on the type of paper
used.
PLAIN PAPER: -10 °C / -5 °C / 0 °C
Adjustment
THICK: -10 °C / -5 °C / 0 °C
Range
ENVELOPE: -10 °C / -5 °C / 0 °C
Adjustment
If fusing performance is poor, increase the setting.
Instructions
If wax streaks occur, decrease the setting.
If offset is poor, decrease the setting.
If curling of the paper occurs, decrease the setting.
Setting
1. Select [TEMPERATURE] and press the Select key.
/procedure
2. Select the type of paper and press the Select key.
3. Select desired setting value with the up key /down key
14.4.15

SUPPLIES REPLACE

A. FUSER UNIT
Function
• Resets the fuser unit counter.
Use
• To use when the fuser unit has been replaced.
1. Select [SUPPLIES REPLACE] → [FUSER UNIT].
Setting
/procedure
2. Press the Select key.
3. Press the Select key and reset the counter.
B. TRANSFER ROLLER
Function
• Resets the transfer roller counter.
Use
• To use when the transfer roller has been replaced.
1. Select [SUPPLIES REPLACE] → [TRANSFER ROLLER].
Setting
/procedure
2. Press the Select key.
3. Press the Select key and reset the counter.
14.4.16

BK CLEAR

Function
• To clear engine information backup data
• Use when the engine information backup data is cleared.
NOTE
Use
• Execute this function to synchronize data when the MFP board or the printer
control board is replaced with a new one.
Setting
1. Select [BK CLEAR] and press the Select key.
/procedure
2. Press the Select key and clear the backup data.
138