Cleaning blade pressure/retraction solenoid (SD5)

1. Remove the left cover.
See P.31
[1]
[2]
7.3.30

Speaker (SP)

NOTE
• Only magicolor 1690MF.
1. Remove the right cover.
See P.32
[3]
[4]
64
[3]
A034F2C056DA
[1]
[2]
A0HFF2C519DA
Field Service Ver. 1.0 Nov. 2008
2. Remove the screw [1] and discon-
nect the connector [2], and remove
the cleaning blade pressure/retrac-
tion solenoid [3].
NOTE
• Use care not to lose the two
springs.
2. Remove the screw [1].
3. Disconnect the connector [2] and
remove two screws [3], and remove
the speaker [4].