REPLACEMENT AND ADJUSTMENT
12.2.2 Inverter Solenoid Adjustment
[B]
1. Turn off the main switch.
2. Place several sheets of paper [A] over the exposure glass area.
3. Lower the feed-out unit (See Feed-out Unit Removal) without
disconnecting the three connectors.
4. Check that the DPS101 is set for the normal mode (1 = ON, 2 = ON, 3 =
OFF, 4 = OFF).
5. Turn on the main switch.
6. Turn off DPS101-1 and 2, then turn on DPS101-3 and 4 [B].
7. Loosen the screw securing the inverter solenoid [C].
8. Press SW101 on the DF main PCB (to engage all DF solenoids), and
adjust the position of the solenoid until the gap [D] (See illustration) is
within 1.5 ± 0.5 mm.
9. Press SW102 on the DF main PCB to turn off all DF solenoids.
10. Turn off DPS101-3 and 4, then turn on DPS101-1 and 2.
[C]