Avaya S8700 Series Installing And Configuring page 35

Hide thumbs Also See for S8700 Series:
Table of Contents

Advertisement

To administer the Ethernet switch(es):
1. Plug the Ethernet switch power cord into the back of the switch and the back of a UPS.
For a single control network—connect Ethernet switch 1 for Control Network A (CNA)
into UPS 1.
For a duplicated control network—connect Ethernet switch 1 for CNA into UPS 1 and
connect Ethernet switch 2 for Control Network B (CNB) into UPS 2.
2. Connect the services laptop computer (RS-232 serial port) to the port labeled Console on
the front of Ethernet switch 1 (CNA) using the flat cable supplied with the Avaya Ethernet
switch.
3. On the services laptop open a VT-100 terminal emulation session.
4. Administer the terminal emulation port settings:
9600 baud
No parity
8 data bits
1 stop bit
5. Follow the instructions in the Quick Start Guide.
6. Set the following parameters:
IP address and subnet mask of the Ethernet switch(es)
- For Ethernet switch for CNA, the defaults are 198.152.254.240, 255.255.0.0.
- For Ethernet switch for CNB, the defaults are 198.152.255.240, 255.255.0.0.
IP address of the trap receiver. (Do not use the Active Server IP address.)
- For Ethernet switch for CNA, this is the IP address of media server 1. (default is
198.152.254.200)
- For Ethernet switch for CNB, this is the IP address of media server 2. (default is
198.152.255.200)
SNMP community string for Get, Set, and Trap. (See the section on SNMP commands
on the documentation CD that comes with the Avaya Ethernet switch.)
Configuring the SNMP subagent in the Avaya Ethernet switch (if used)
Issue 4.1 June 2005