Stop Buffer On Tank Housing (Ms 201) - Stihl MS 201 Manual

Hide thumbs Also See for MS 201:
Table of Contents

Advertisement

9.5
Stop Buffer on Tank
Housing (MS 201)
2
1
: Remove the screw (1) from the
underside of the machine.
– Screw (1) is secured with
Loctite. Preheat with a hot air
blower if necessary.
: Pull the bearing plug (2) out of its
seat.
2
: Lift the handle housing (1)
slightly.
: Pry out and replace the stop
buffer (2).
MS 201, MS 201 C, MS 201 T, MS 201 TC
Installing
– Coat taper and lug of stop buffer
with STIHL press fluid, b 14
: Position the stop buffer (1) so
that the lug (arrow) points in the
direction of the fan housing.
1
: Push the stop buffer (1) into its
seat until the lug is firmly seated
1
in the opening (arrow).
1
2
1
: Push the bearing plug (1) into its
seat (arrow) on the underside of
the machine.
: Coat the screw (2) with Loctite, fit
it and tighten it down firmly, b 14
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 201 t