Annular Buffer On Handlebar; Stop Buffer (Ms 200) - Stihl MS 200 Service Manual

Hide thumbs Also See for MS 200:
Table of Contents

Advertisement

1
: Take out the screws (arrows).
– Remove the ground wire (1).
– Check the annular buffer and
replace if necessary
1
– Line up the buffer so that it faces
the handle housing and the notch
engages on the rib (arrow).
: Fit the annular buffer (1) in
position.
– Fit the ground wire (1) in position.
: Insert screws (arrows) and
tighten them down firmly.
MS 200, MS 200 T
The ground wire must butt against
the rib (2).
: Tighten down the screw (1) firmly.
Do pinch the short circuit wire.
– Fit the handle molding, b 12.3
– Reassemble all other parts in the
reverse sequence.
– Tightening torques, b 3.5
11.3
Annular Buffer on
Handlebar
– Remove the fan housing, b 10.2
1
: Take out the screw (arrow).
2
– Ease the handlebar to one side.
Do not use wrench at the side with
the tapped hole
1
– it would damage the annular
buffer.
: Apply 20 mm open end wrench,
loosen and unscrew the annular
buffer (1).
– Check the annular buffer (1) and
replace if necessary
– Reassemble in the reverse
sequence.
11.4
– Remove the chain sprocket
cover, bar and chain, b 5
: Remove the screws (arrows)
from the annular buffers on the
fuel and oil tanks.
1

Stop Buffer (MS 200)