LN1000 Mobile Secure Router
LN1000 Rear Transition Module Console Ports
Table 4: Pinouts for the RJ-45 (NPU), shMM, and IPMC Console Port Connectors
Pin
Setting
1
NC
2
RXD
3
TXD
4
NC
5
GND
6
NC
10
Figure 5: LN1000 Rear Transition Module — Back View
Connector
The shMM console port is the console port for the optional shMM module on the RTM.
The settings are baud rate of 19200 8N1, no flow control. You can use this port to send
and receive debug console commands to and from the shelf manager.
The IPMC console port is the console port for the IPMC controller on the LN1000 board.
The settings are baud rate of 115200 8N1, no flow control. This is a debug output only
port.
The RS-232 console port, labeled NPU, accepts an RJ-45 connector and is located on
the front panel of the LN1000 rear transition module. The settings are baud rate of 9600
8N1, no flow control. You can use this console port to monitor system startup and for
system repair. This console port is also available from the front panel of the LN1000
router.
Figure 6: LN1000 Rear Transition Module — Front Panel
Locking screw
USB port
Ejector latch
ShMM IPMC NPU
Description
No connect.
Transmit data into the LN1000 router.
Transmit data out from the LN1000 router.
No connect.
Ground.
No connect.
IPMI Shelf Manager
LINK
7
6
5
4
3
Ethernet ports
ACT
PWR OK
Locking screw
2
1
0
Ejector latch