Removal procedure: outdoor unit ERYQ005~007AAV3
2.4

Removal of the Electrical Box

1
Warning
Procedure
Step
Procedure
Remove the top panel and
the front panel.
1 Remove the shield plate.
3
1
Loosen the 2 screws.
2
Slide the cover upward
to undo the one hook on
the bottom left, and
then remove the plate.
5 5
3
Disconnect the 2 power
supply cables and the 1
earth wire.
4
Disconnect the 2 earth
wires.
5–14
Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Points
Shield
plate
Earth wires