Installing The I/O Modules - Juniper E Series Hardware Manual

Routing platforms
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

E-series Hardware Guide

Installing the I/O Modules

52
!
Installing Components for Line Module Redundancy
Figure 27: Installing a redundancy midplane
Redundancy
midplane
To install the I/O modules in a redundancy group:
1. Install the redundancy I/O module in the lowest-numbered slot of the
redundancy group.
When setting up a redundancy group with line modules, be sure to
CAUTION:
install the redundancy I/O module in the lowest-numbered slot of the redundancy
group. It is possible to install the redundancy I/O module in other slots; however,
doing so may damage other I/O modules connected to the redundancy midplane.
2. Install the corresponding I/O module for the line module of each slot in the
redundancy group. (See
chapter.)
3. Cable each module to provide a path to the remote interface (see Chapter 6,
Cabling E-series Routers).
Installing a Line Module or an I/O
Module, earlier in this

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Erx-1440Erx-705Erx-710Erx-1410Erx-310

Table of Contents