Juniper E Series Hardware Manual page 119

Routing platforms
Hide thumbs Also See for E Series:
Table of Contents

Advertisement

For example, an OCx/STMx line module can pair with either an OC3-4 or an
OC12/STM4 I/O module. Consequently, the line module has four port status LEDs
for OC3/STM1 operation. However, only the top set of port status LEDs are active
during OC12/STM4 operation.
Table 12 shows the functions of the module and port status LEDs.
Table 12: LED identification and activity descriptions
LED Location
LED Label
All modules
OK
FAIL
ONLINE
All modules
REDUNDANT
SRP module
POWER A OK
POWER B OK
FAN OK
FAN FAIL
LINK
ACTIVITY
Ethernet line
LINK
modules
ACTIVITY
HSSI line
SYNC
module
YEL ALM
RED ALM
LED Indicator
LED Color
Module status
Green
Module status
Red
Module status
Green
Redundancy
Green
Power
Green
Power
Green
Fan
Green
Fan
Red
When the LED alternates between OK and FAIL in ten second intervals, a
NOTE:
non-critical fan failure exists.
Ethernet
Green
Ethernet
Green
Ethernet
Green
Ethernet
Green
Port status
Green
NOTE:
This LED is not functional on the HSSI line module.
Port status
Red
OFF to ON
ON to OFF
Self-test passed
Failure detected
Failure detected
Diagnostic test running
Module online
Module offine
See
Redundancy Status
later in this chapter.
NOTE:
The REDUNDANT LED on the cOCx/STMx, FE-8,
GE/FE, HSSI, OCx/STMx, and X.21/V.35 line modules is
nonfunctional.
Power online on source A
Power off
Power online on source B
Power off
Fan online
Critical fan failure
Critical fan failure
Fan online
Ethernet link up
Ethernet link down
Blinks when Ethernet traffic
No Ethernet traffic on link
on link
Ethernet link up
Ethernet link down
Blinks when Ethernet traffic
No Ethernet traffic
on link
on link
If the port is configured as
If the port is configured as
DTE, the LED lights when
DTE, the LED goes out
both the DCE and the clock
when either the DCE or the
source are available.
clock source becomes
unavailable.
If the port is configured as
DCE, the LED lights when
If the port is configured as
the DTE is available.
DCE, the LED goes out
when the DTE becomes
unavailable.
If the port is configured as
If the port is configured as
DTE, the LED lights when
DTE, the LE goes out when
either the DCE or the clock
both the DCE and the clock
source becomes
source are available.
unavailable.
If the port is configured as
If the port is configured as
DCE, the LED goes out
DCE, the LED lights when
when the DTE is available.
the DTE becomes
unavailable.
Understanding Status LEDs to Troubleshoot
Chapter 10: Troubleshooting
!
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Erx-1440Erx-705Erx-710Erx-1410Erx-310

Table of Contents