Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
PoweronTaskIndex = 0
[StartupConfiguration]
OEM software in the range from 12 to 24 can be started in this section.
The [StartupConfiguration] section is subdivided as follows:
0 to 12
12 to 24
25 to 32
33 to 47
Example:
Startup33 = name := ITS, Timeout :=15000
Startup34 = name := HMIVers, Cmdline := "/StartUp", Timeout :=10000
[TaskConfiguration]
; 3. bar
; Task16 = name := oemframe, cmdline := "sysmeter", Timeout := 10000,
; ClassName := "SysMeter", HeaderOnTop := False, PreLoad := False
The 3rd horizontal softkey bar is only displayed if a task or the EXIT button is
assigned to Task 16 or higher in the bar.
; 4th bar : allocated to task 96 - 103
;Task96 = name := oem, Timeout := 10000
;Task97 = name := oem, Timeout := 10000
;Task98 = name := oem, Timeout := 10000
;Task99 = name := oem, Timeout := 10000
;Task100 = name := oem, Timeout := 10000
;Task101 = name := oem, Timeout := 10000
;Task102 = name := oem, Timeout := 10000
;Task103 = name := oem, Timeout := 10000
The 4th horizontal softkey bar is only displayed if a task or the EXIT button is
assigned to Task 96 or higher in the bar.
The Task 50 to Task 87 entries can be used by OEMs.
[CommandToTask]
plc_select = #13
Cycles = #14
In this section, you can specify that the HMI will be started from the NCU via the
command channel.
Further information: see "Activating Dialog Screen from NC Program"
IM4/2-108
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
; index of task started by the regie after power on
; (may differ in some circumstances from the default task index,
; which is the task index from [TaskConfiguration] with the lowest number.
Reserved for expansions by Siemens
Available for OEM applications
Reserved for simulation
Reserved for Siemens applications (in the ADD_ON directory)
; only necessary for HMI startup through NCU via command channel