Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
The file "mbdde.ini" is evaluated on startup. The unused alarm files and the current
log file are located in the mmc2 directory. The names of these hidden files
(attribute "hidden") consist of an 8-digit hexadecimal number with the extension
".alr". The names of files in which write errors are detected on startup also consist
of an 8-digit hexadecimal number, but with the extension ".al_".
Log file size
The size of the log file (ring buffer) can be defined in the MBDDE.INI file.
[Alarms]
Records = value
With standard value 150, 75 alarms can be displayed. 2 records are needed for
each alarm.
Selection of alarms by feature
Filter entries in MBDDE.INI can be used to control the messages logged in the log
file.
[PROTOCOL]
Filter=Expression
Expression expresses selection features and is constructed as follows:
Syntax
[IDENTIFIER][RELATION][FEATURE][OPERATORS]
IDENTIFIER:
No.
Prio
Mode
Type
From
AckVar
RELATION:
':'
'<'
'>'
'!'
FEATURE:
Numbers
Strings
IM4/2-56
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
; Size of log file
Default value:
Minimum value:
Maximum value:
Alarm number
Priority
Message line/alarm line or dialog box
Alarm type (PowerOn, Cancel, etc.)
Source of alarm
Acknowledgment variable
Equal to
less than
greater than
Not
150
18
32000
© Siemens AG, 2005. All rights reserved
08/2005