08/2005
[DriveTextFiles]
ALDEV_80E5=f:\dh\mb.dir\aldvs_
ALDRV_80E5=f:\dh\mb.dir\aldrs_
;ALDEV_808F=f:\dh\mb.dir\aldvu_
;ALDRV_808F=f:\dh\mb.dir\aldru_
ALDEV_x=f:\dh\mb.dir\aldvp_
ALDRV_x=f:\dh\mb.dir\aldrp_
[IndexTextFiles]
ALNX=f:\dh\mb.dir\alnx_
ALSI=f:\dh\mb.dir\alsi_
[DEFAULTPRIO]
CANCEL=100
RESET=100
POWERON=100
NCSTART=100
PLC=100
PLCMSG=100
MMC=100
[PROTOCOL]
Filter=Expression
Records=150
DiskCare=−1
The multiple file strategy can also be selected by means of the DiskCare entry in
the Ini file.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
; drive- and device type-specific alarm text files
; default definition of the priorities of the different alarm types
; This section defines different characteristics of the log that
; specifies how particular error messages are to be registered.
For details on formation of filter expressions for control of message
volume, refer to "Outputting the Alarm Log."
; Criteria for selecting the alarm messages to be recorded. The notation
; is described in SINUMERIK 840D OEM package HMI User's Manual.
; Characterizes the numbers of entries in the log file. If the actual
; number exceeds this value, the server starts to overwrite old entries
; (principle: ring buffer)
; Mode of alarm log writing
; if a number less than -1 is specified, this number of log files is
; kept in parallel, and one of them is actually used
; if -1 is specified, the log file is not automatically updated
; if 0 is specified, the log file is immediately updated
; if a number greater than 0 is specified, the log file is updated after the
; specified number of seconds elapses with no intermediate alarm state
; changes. The log file is always updated when you send the
; DDE command "AlarmProt" to the MBDDE server
; (principle: ring buffer) ---------------------------------------------------------------
# attention: the mode changed from V4 to V5 !
Commissioning HMI Advanced (IM4)