Commissioning HMI Advanced (IM4)
2 Setting Functions and Parameters
2.2.9 Inverting Spindle Icon of Spindle Display
Function
The spindle icon display can be inverted using channel-specific machine data
9033:MA_DISPL_INVERT_DIR_SPIND_M3: normal or inverted display is possible.
For example, if you want the same icon to be displayed at M4 for the counter-
spindle as at M3 for the main spindle, set bit[n]=1 (see inverting M3/M4 at the
control interface).
9033
MD number
Default value: 0x0000
Change effective after: IMMEDIATE
Data type: LONG
Meaning
2.2.10 Keyboard Behavior for HMI Advanced
CAPSLOCK (PCU 50/PCU 70)
The CAPSLOCK function allows all entries made with external SINUMERIK
keyboards to be in upper case instead of lower case. If lower case letters are
needed, they can be added by means of the SHIFT commands function.
This function is only active when HMI Advanced is running. It is not active in
standard Windows NT/XP operation.
Activation
This function is activated by display MD 9009: MM_KEYBOARD_STATE
0: CAPSLOCK off
2: CAPSLOCK on
This display MD is only evaluated on during startup. If the MD is changed, the
system must be restarted.
IM4/2-44
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
MA_DISPL_INVERT_DIR_SPIND_M3
Spindle rotation direction display
Min. input value: 0x0000
Protection level (R/W) 3/4
Applies from version 6.2
Spindle rotation direction display:
Bit[n]=0
M3 displayed as clockwise rotation in the icon
Bit[n]=1
M3 displayed as counter-clockwise rotation in the icon
n = spindle number – 1 (i.e. bit 0 is spindle S1)
Note:
With the corresponding setting for MD 9014:
USE_CHANNEL_DISPLAY_DATA
MD 9033 can be managed channel-specifically in the NC.
Max. input value: 0x7FFFFFFF
Unit: -
© Siemens AG, 2005. All rights reserved