Siemens SINUMERIK 840D sl Commissioning Manual page 426

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Commissioning HMI Advanced (IM4)
2 Setting Functions and Parameters
Configuring OEM texts in the header
The machine manufacturer can display his own texts in the program directory and
program name lines. These texts cannot include % parameters as is possible in
user texts. The lines are divided into <OEM_NUMBER_TEXTFIELD> areas
according to the entry in HEADER.INI.
Chan 1 Machine
Machine
Channel RESET
STOP: No NC RESET
NCK has not ramped up
Figure 2-4
Example of OEM text
The data are provided in a user PLC DB. The number of the data block and the
exact offset are declared in the HEADER.INI file.
The following entries are available in the [OEMTextInfo] section for this purpose.
OEM_NUMBER_TEXTFIELD = 1 ; maximum of 3 text fields per line
OEM_TEXT_BASE = DBx.DBBy
The interface in the user DB has the following format:
Start-DBB Byte
Or
Start-DBB +18 Byte
Start-DBB +1
Or
Start-DBB +19
Start-DBB + 3 String
Or
Start DBB+20 Double Word
The first parameter contains an offset for a text number with a base of 700,000
(user PLC texts). If this parameter = 0, the corresponding line is deleted. The
second parameter contains a maximum 12-character string. Unless empty, this text
is output instead of the user PLC text.
The parameters must be written from "back to front" in the PLC, i.e., all parameters
must be initialized before the first byte is set. The data for the next line are located
exactly 18 bytes after the start byte. The lines are output from left to right; a
maximum of three output fields per line are provided (i.e., a total of 6 fields are
possible).
A hotlink to the first byte for each line is set up in the HMI. If a change occurs in
that byte, the HMI reacts. If the HMI has displayed the data, it writes a –1 to the
first variable. The HMI is informed about this change by means of the hot link,
whereupon it writes a 0 to this variable.
IM4/2-32
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
Bit 0=1: there is something to do
All Bits=1: job is acknowledged by HMI
All Bits=0: PLC can write to interface again
Word
Offset for text from alpu_xx.com to be displayed;
700 000 is the base address and is always
Word
summed internally
All Bits=0: Delete line
String containing a maximum of 12 characters
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810dSinumerik 840diSinumerik 840d

Table of Contents