Cisco Nexus 5000 Series Interfaces Command Reference - Cisco Nexus 5000 Series Command Reference Manual

Interface
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

show interface ethernet
This example shows how to display the purpose of a specified subinterface:
switch# show interface ethernet 1/5.2 description
-------------------------------------------------------------------------------
Port
-------------------------------------------------------------------------------
Eth1/5.2
switch#
This example shows how to display the switchport information for a specific interface:
switch# show interface ethernet 1/2 switchport
Name: Ethernet1/2
Switchport: Enabled
Switchport Monitor: Not enabled
Operational Mode: trunk
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: 1,300-800
Pruning VLANs Enabled: 2-1001
Administrative private-vlan primary host-association: none
Administrative private-vlan secondary host-association: none
Administrative private-vlan primary mapping: none
Administrative private-vlan secondary mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Monitor destination rate-limit: 1G
switch#
In the above display, the Monitor destination rate-limit field displays the rate limit configured on a switchport
interface on a Cisco Nexus 5010 Series switch.
Note
You can configure the monitor destination rate-limit only on a Cisco Nexus 5010 Series switch or Cisco
Nexus 5020 Series switch.
This example shows how to display the information about a specific Ethernet interface that is bound to a
virtual Ethernet interface:
switch(config)# interface vethernet 10
switch(config-if)# bind interface ethernet 1/5 channel 10
switch(config-if)# inherit port-profile ppVEth
switch(config-if)# untagged cos 3
switch(config-if)# exit
switch(config)# exit
switch# show interface ethernet 1/5 brief
--------------------------------------------------------------------------------
Ethernet
Interface
--------------------------------------------------------------------------------
Eth1/5
switch#
The following table describes the significant fields in the above display.

Cisco Nexus 5000 Series Interfaces Command Reference

118
Type
Speed
Description
eth
10G
Eth 1/5.2 subinterfaces
VLAN
Type Mode
Status
--
eth
routed down
Reason
SFP not inserted
Show Commands
Speed
Port
Ch #
10G(D) 10