realize overtravel protection by software.
(2) Masking overtravel protection function
To set 2008h-28h =0.

7.1.5 Jog operation procedure

1) Panel jog function
Step
Check wiring of main circuit and power supply of
1
control circuit (L1C, L2C) is powered on, and power
supply of main circuit (R/L1, S/L2, T/L3) is powered on.
Press MODE key, to enter auxiliary function section
2
So-□□
3
Press UP or DOWN key to find So-13 (Jog speed)
Press SET key for 0.5s to enter setting interface, to set
4
safety value of jog speed by press UP or DOWN key.
Press SET key for 0.5s to confirm the setting speed, and
5
return to So-13.
6
Press UP key to display So-14 (jog run)
7
Press SET key for 0.5s to jog run.
Press UP key to jog forward run; press DOWN key to jog
8
reverse run.
9
Press MODE key, and servo is OFF, to quit JOG mode.
2008h-0Eh
Note: 1. internal jog mode is a special speed mode, jog speed is related to decel. time Po109, Po110.
Content
JOG speed
Setting range
0~30000
Function code
So-13
FL20-C Series
PP
PV
PT
Setting unit
0.1rpm
Mapping
N
117
Remarks
Please refer to 5.2.1
The Mfr's value is 100rpm
Note: the unit of speed is
0.1rpm.
JOG is displayed, servo is
enabled.
To
confirm
direction.
CSP
CSV
Mfr's value
When enabled
1000
Immediate
Data type
UINT16
RW
rotating
CST
HM
Accessibility