6084h
00h
7.4.2 Related functions
Index
Sub-index
606Dh
00h
606Eh
00h
7.4.3 Recommended configuration
RPDO
6040h: control word
60FFh: target velocity
6083h: profile acceleration
6084h: profile deceleration
6060h: modes of operation
7.5 Profile torque mode (PT)
In this mode of operation, the controller gives the target torque in 6071h to the servo drive.
Torque control is performed by the servo drive. The servo drive will supply actual position
value, actual velocity value and actual torque value.
Profile
deceleration time
Name
When the difference between 60FFh (converted
Velocity
into motor speed/RPM) and actual motor speed
threshold
is within ±606Dh, and the time reaches 606Eh,
the servo drive considers that the speed
reference is reached, sets status word 6041h
bit10 = 1 and activates the speed reached DO
Velocity
signal.
window
This flag bit is valid only when the S-ON signal
is valid in profile position mode and cyclic
synchronous velocity mode.
RW
UINT16
Description
TPDO
6041h: status word
6064h: position actual value
606Ch:velocity actual value
6061h: Modes of operation display
147
ms
0~32000
Remarks
Mandatory
Mandatory
Optional
Optional
Optional
Optional
Optional
100