[AL. 037_Parameter error]

• Servo parameter setting value is incorrect.
[AL. 037.1_Parameter setting range error]
Cause
1.
The servo parameter was set outside of the
setting range.
2.
Inconsistent combination of the servo
parameters that have been set.
3.
The setting value of the servo parameter has
changed due to the servo amplifier
malfunction.
[AL. 037.2_Parameter combination error]
Cause
1.
Inconsistent combination of the servo
parameters that have been set.
[AL. 037.6_Parameter mismatch error]
Cause
1.
Mismatching with the saved parameters
occurred because of the error in writing
parameters.
2.
The setting value of the parameter changed as
the servo amplifier malfunctioned.
[AL. 037.7_Network parameter setting error]
Cause
1.
An error exists in the network parameter
setting.
2.
The setting value of the network parameter
changed as the servo amplifier malfunctioned.
Check/action method
[A]: Check the servo parameter error No. display screen of the servo amplifier
display section, the MR Configurator2 alarm display screen, and other relevant
screens and review the servo parameter setting value.
[G] [WG]: Check the servo parameter error No. and review the setting value of
the servo parameter on the alarm display screen of MR Configurator2 or
others.
[A]: Check the servo parameter error No. display screen of the servo amplifier
display section, the MR Configurator2 alarm display screen, and other relevant
screens and review the servo parameter setting value.
[G] [WG]: Check the servo parameter error No. and review the setting value of
the servo parameter on the alarm display screen of MR Configurator2 or
others.
Replace the servo amplifier.
Check/action method
[A]: Check the servo parameter error No. display screen of the servo amplifier
display section, the MR Configurator2 alarm display screen, and other relevant
screens and review the servo parameter setting value.
[G] [WG]: Check the servo parameter error No. and review the setting value of
the servo parameter on the alarm display screen of MR Configurator2 or
others.
Check/action method
[A]: Check the parameter error No. on the servo amplifier display, the alarm
display screen of MR Configurator2, and others. Rewrite the setting value
because the value before or after writing has been displayed.
[G] [WG]: Check the servo parameter error No. on the alarm display screen of
MR Configurator2 or others. Rewrite the setting value because the value
before or after writing has been displayed.
Replace the servo amplifier.
Check/action method
Check if the setting value of the network parameter is within the setting range.
[A]: Check the parameter error No. on the parameter error No. display screen
of the servo amplifier display, the alarm display screen of MR Configurator2,
and others. Rewrite the setting value because the value before or after writing
has been displayed.
[G] [WG]: Check the servo parameter error No. on the alarm display screen of
MR Configurator2 or others. Rewrite the setting value because the value
before or after writing has been displayed.
Replace the servo amplifier.
1 SERVO AMPLIFIER TROUBLESHOOTING
1.3 Handling methods for alarms/warnings
1
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]