[AL. 046_Servo motor overheat]

• The servo motor overheated.
[AL. 046.1_Abnormal temperature of servo motor 1]
Cause
1.
Ambient temperature of the servo motor has
exceeded the specified value.
2.
The servo motor is overloaded.
3.
The thermal sensor in the encoder is
malfunctioning.
[AL. 046.2_Abnormal temperature of servo motor 2]
Cause
1.
Ambient temperature of the servo motor has
exceeded the specified value.
2.
The servo motor is overloaded.
[AL. 046.3_Thermistor disconnected error]
Cause
1.
A servo motor thermistor wire is not
connected.
2.
A servo motor thermistor wire is disconnected.
[AL. 046.4_Thermistor circuit error]
Cause
1.
A thermistor circuit of the servo amplifier is
malfunctioning.
[AL. 046.5_Abnormal temperature of servo motor 3]
Page 46 [AL. 046.1_Abnormal temperature of servo motor 1]
[AL. 046.6_Abnormal temperature of servo motor 4]
Cause
1.
An electrical current was applied to the servo
motor in excess of continuous output current.
1 SERVO AMPLIFIER TROUBLESHOOTING
46
1.3 Handling methods for alarms/warnings
Check/action method
Check the ambient temperature of the servo motor, and if the temperature
exceeds the specified value, lower the ambient temperature.
Check the effective load ratio.
If the effective load ratio exceeds 100 %, reduce the load or review the
operation pattern.
Replace the servo motor.
Check/action method
Check the ambient temperature of the servo motor. If the ambient temperature
exceeds the specified value, lower the ambient temperature.
Check the effective load ratio.
If the effective load ratio exceeds 100 %, reduce the load or review the
operation pattern.
Check/action method
Check if the servo motor thermistor wire is connected.
Check for disconnection in the servo motor thermistor wire. If the servo motor
thermistor wire is disconnected, repair the wire.
Check/action method
Replace the servo amplifier.
Check/action method
Check the effective load ratio.
If the effective load ratio is high, reduce the load or review the operation
pattern. Otherwise, replace the servo motor with a larger-capacity servo motor.