[AL. 012_Memory error 1 (RAM)]
• The internal parts of the servo amplifier (RAM) have malfunctioned.
[AL. 012.1_RAM error 1]
Cause
1.
The internal parts of the servo amplifier has
malfunctioned.
2.
There is an abnormality in the surrounding
environment.
[AL. 012.2_RAM error 2]
Page 15 [AL. 012.1_RAM error 1]
[AL. 012.4_RAM error 4]
Page 15 [AL. 012.1_RAM error 1]
[AL. 012.5_RAM error 5]
Page 15 [AL. 012.1_RAM error 1]
[AL. 012.6_RAM error 6]
Page 15 [AL. 012.1_RAM error 1]
[AL. 012.7_RAM error 7]
Page 15 [AL. 012.1_RAM error 1]
[AL. 012.8_RAM error 8]
Page 15 [AL. 012.1_RAM error 1]
Check/action method
Noise from the power supply may have caused the failure. Disconnect the
cables except for the control circuit power supply, and then check the
repeatability. If the failure continues, the servo amplifier may have
malfunctioned. Replace the servo amplifier.
Check the power supply for noise. If there is noise, take countermeasures to
reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
1 SERVO AMPLIFIER TROUBLESHOOTING
1.3 Handling methods for alarms/warnings
1
Model
[A]
[G]
[WG]
15