[AL. 098_Software position limit warning]
• A software position limit, which is set with a servo parameter, is reached.
[AL. 098.1_Forward rotation-side software stroke limit reached]
Cause
1.
A software position limit was set within the
actual operation range.
[AL. 098.2_Reverse rotation-side software stroke limit reached]
Page 68 [AL. 098.1_Forward rotation-side software stroke limit reached]
1 SERVO AMPLIFIER TROUBLESHOOTING
68
1.3 Handling methods for alarms/warnings
Check/action method
Check if [Pr. PT15] and [Pr. PT17] are set correctly.
Model
[G]
[WG]