[Al. 017_Board Error] - Mitsubishi Electric Melservo-J5 MR-J5 Series User Manual

Troubleshooting
Hide thumbs Also See for Melservo-J5 MR-J5 Series:
Table of Contents

Advertisement

[AL. 017_Board error]

• A part in the servo amplifier is malfunctioning.
[AL. 017.1_Board error 1]
Cause
1.
The current detection circuit is malfunctioning.
2.
There is an abnormality in the surrounding
environment.
[AL. 017.3_Board error 2]
Page 20 [AL. 017.1_Board error 1]
[AL. 017.4_Board error 3]
Cause
1.
The recognition signal of the servo amplifier
was not read properly.
2.
There is an abnormality in the surrounding
environment.
[AL. 017.5_Board error 4]
Cause
1.
Rotary switches (SW1/SW2) are
malfunctioning.
2.
There is an abnormality in the surrounding
environment.
[AL. 017.6_Board error 5]
Cause
1.
The DIP switch (SW3) is malfunctioning.
2.
There is an abnormality in the surrounding
environment.
[AL. 017.7_Board error 7]
Page 20 [AL. 017.4_Board error 3]
1 SERVO AMPLIFIER TROUBLESHOOTING
20
1.3 Handling methods for alarms/warnings
Check/action method
Check that this alarm occurs in the servo-on status. If the alarm occurs, the
servo amplifier may have malfunctioned. Replace the servo amplifier.
Check the noise, ambient temperature, and others, and implement appropriate
countermeasures for the cause.
If there is noise, take countermeasures to reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Check/action method
Disconnect the cables except for the control circuit power supply, and then
check the repeatability. If the failure continues, the servo amplifier may have
malfunctioned. Replace the servo amplifier.
Check the noise, ambient temperature, and others, and implement appropriate
countermeasures for the cause.
If there is noise, take countermeasures to reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Check/action method
After checking the conditions of the rotary switches, cycle the power, and then
check the repeatability. If the failure continues, the servo amplifier may have
malfunctioned. Replace the servo amplifier.
Check the noise, ambient temperature, and others, and implement appropriate
countermeasures for the cause.
If there is noise, take countermeasures to reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Check/action method
After checking the conditions of the DIP switch, cycle the power, and then
check the repeatability. If the failure continues, the servo amplifier may have
malfunctioned. Replace the servo amplifier.
Check the noise, ambient temperature, and others, and implement appropriate
countermeasures for the cause. If there is noise, take countermeasures to
reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]
Model
[G]
[WG]
Model
[G]
[WG]

Advertisement

Table of Contents
loading

Table of Contents