[AL. 096_Home position setting warning]

• Homing failed.
[AL. 096.1_In-position warning at homing]
Cause
1.
At the time of homing, INP (In-position) did not
turn on within the specified time.
[AL. 096.2_Command input warning at homing]
Cause
1.
A command was inputted at the time of
homing.
2.
Creep speed is high.
[AL. 096.3_Servo off warning at homing]
Cause
1.
An attempt to execute a homing was made
during servo-off.
[AL. 096.4_Magnetic pole detection incomplete warning at homing]
Cause
1.
Z-phase was not turned on after servo-on.
Check/action method
Adjust gains so that the droop pulses are set within the In-position range.
Remove the cause of droop pulse occurrence, and then perform homing.
Check/action method
Avoid commands to be inputted at homing.
Decelerate the creep speed, and then perform homing.
Check/action method
After servo-on, execute the homing.
Check/action method
Rotate the direct drive motor to turn on the Z-phase, and then perform homing.