3-19.
INFORMATION
MODE
(CONT.)
July 2003
Press ▼ to view the specific status of each input. An underscore
("_") indicates the input is not presently detected. A checkmark
("√") indicates the signal is detecting a normal input. A blinking
("X") indicates the signal is presently detected, but is detected
as a half-wave (partially failed) input.
The V, H, D, S, F, P and M signals are wired in series.
The first signal missing out of this sequence generally
causes all signals to the right of it to be missing as well.
Press ► to continue onto OUTP H* P_.
6. OUTP F*I*H*P_
This mode displays the status of components and outputs. If the
output signal is detected, an identifying letter is displayed (see
below), followed by an "*". If the output is off, "_" is displayed.
"F" = Fan output
"I" = Ignition modules output
"H" = Heat output
"P" = Pressure output
If fan is on, "F*" shows in display. If fan is off, "F_" shows
in display. If controls sense a problem with the fan output,
"F*"shows in display, with the "*" flashing.
When ignition modules are on, "I*" shows in the display. If
ignition modules are off, "I_" shows in display. If controls sense
a problem with an ignition module, "I*" shows in the display
with "*" flashing.
If heat is on, "H*" shows in display. If heat is off, "H_" shows
in display. If controls sense a problem with the heat output,
"H*" shows in display, with the "*" flashing.
If pressure is on, "P*" shows in display. If pressure is off, "P_"
shows in display. If controls sense a problem with the pressure
output, "P*" shows in display, with the "*" flashing.
Press ▼ to view the amp "DRAW" status of each output. "H√"
and "P√" in the display means the amps are good. A flashing
"X" behind the H or P means too much current.