2-9.
GAS PRESSURE
REGULATOR
SETTING
(CONT.)
Figure 1
Figure 2
Figure 3
March 2014
MEASURING GAS PRESSURE
1.
Locate the pressure tap hole or fitting on the side of the gas
valve. Remove the pipe plug from the valve or fitting circled
in Figure 1.
2.
Screw a pressure tap fitting into the valve or the fitting on
the side of the valve circled in Figure 2.
3.
Place one end of a vacuum hose on the pressure tap fitting
and the other end on the manometer as shown in Figure 3.
4.
Turn the fryer "ON".
5.
Allow the fryer to reach full burn.
6.
The pressure reading on the manometer should be 3.5" of
water column for Natural gas and 10" of water column for
LP gas.
7.
Turn the fryer off.
8.
Remove the pressure tap fitting.
9.
Place the pipe plug back into the valve or the fitting on the
valve.
Notify a qualified service technician if gas pressure
differs from factory settings mentioned in this manual