Henny Penny OFE-391 Operator's Manual page 58

Open fryer
Table of Contents

Advertisement

3-17.
SPECIAL
PROGRAM
MODE
(CONT.)
April 2003
PRODUCT BUTTONS (SP-9)
This mode allows you set up the way products are selected, and
Cook Cycles started, in the cook mode.
a.
Follow steps 1 and 2 above.
b.
Press and release (PROG►) until "SP-9" and "PRODUCT
BUTTONS" flash in the display.
c.
When using the first option, "1,COOK", pressing a product
button displays that product and starts the Cook Cycle.
When nothing is cooking, no product displays.
d.
Press ▼▲ to show the second option. If using
"2,SELECT", pressing a product button displays the product
only. Press TIMER button to start the Cook Cycle.
CLEAN-OUT MINUTES (SP-10)
This allows you to set the number of minutes of the Clean-Out
Mode.
a.
Follow steps 1 and 2 above.
b.
Press (PROG►) until "SP-10" and "CLEAN-OUT
MINUTES" show in display, along with the preset minutes.
c.
Press ▼▲ to change the number of minutes, up to 99.
CLEAN-OUT TEMPERATURE (SP-11)
This allows you to set the temperature of the Clean-Out Mode.
a. Follow steps 1 and 2 above.
b. Press (PROG►) until "SP-11" and "CLEAN-OUT TNP"
show in display, along with the set temperature.
c. Press▼▲ to change the temperature, up to 195°F (91°C).
NOMINAL AMPS READING (SP-12)-NOT USED ON
MODEL 391
"SP-12", "AMPS RDG, NOMINAL" should show on the left
side of display, and "OFF" on the right side.
AMPS READING LOW LIMIT (SP-13)-NOT USED ON
MODEL 391
"SP-13" and "AMPS RDG, LOW LIMIT" should show on the
left side of display, and "OFF" on the right side.
AMPS READING HIGH LIMIT (SP-14)-NOT USED ON
MODEL 391
"SP-14" and "AMPS RDG, HIGH LIMIT" should show on the
left side of display, and "OFF" on the right side.
51

Advertisement

Table of Contents
loading

Table of Contents