Lift Motor Replacement; About; Specification; Lift Motor Fuse - Precor Experience 700 line Series Service Manual

Hide thumbs Also See for Experience 700 line Series:
Table of Contents

Advertisement

Lift Motor Replacement

About

This procedure provides instruction to remove and replace the Lift Motor.

Specification

System Component
Lift Motor Calibration Distance*
Note: * Calibration distance is specified at incline level 0.

Lift Motor Fuse

he lift motor fuse (2 Amp) is located on the
bottom cover to access the fuse. Use a small standard screwdriver to unsnap the clip fasten-
ers and remove the cover.
1
Lower printed circuit assembly; generally this refers to the lower board. On treadmills, this is
the motor controller unit (MCU), and on self-powered units, it is the main board in the lower
section.
2
Motor controller or motor controller module
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Specification
1 1/8 in - 1 3/16 in (2.8 cm - 3.0 cm)
1
LPCA
board in the
MC
6 Replacement Procedures
Lift Motor Replacement
2
module. Remove the MC
Page 147