Module-ID = ATE RC = 4
The
routine logs this error during an
send
file transfer when it has attempted
XMODEM
to send a sector nine times, but the receiving
site has not acknowledged receipt of the data.
Verify that both sites are using the
file transfer protocol. Restart the remote site
and be sure that it is ready to receive. Select
and try the file transfer again.
send
Module-ID = ATE RC = 5
The
routine logs this error during an
send
file transfer when it has attempted
XMODEM
to send an EOT (end of transmission) nine
times but the receiving site has not
acknowledged receipt of the EOT.
See if the file has been received on the remote
end. If it has, no further action is necessary. If
it has not, restart the remote site and then
select
and try the file transfer again.
send
Module-ID = 6 RC = 6
The
routine logs this error when
send
beginning an
XMODEM
character is received for 100 seconds. The
receiving site must transmit a specified start
character to indicate that it is ready to receive.
Verify that both the local and remote sites are
using the
XMODEM
receiving site is ready to receive. Then restart
the file transfer.
Module-ID = ATE RC = 7
The
routine logs this error when no
receive
data arrives in
30
transfer or
seconds for an
100
transfer.
Appendix B. Error Log Entries
XMODEM
file transfer if no start
protocol and that the
seconds for a pacing file
XMODEM
file
B-25