IBM RT PC Problem Determination Manual page 262

Hide thumbs Also See for RT PC:
Table of Contents

Advertisement

5-12 AIX Operating System Problem Determination Guide
22
Invalid length field in the DDA entry (non-fatal)
Cause: A module that has been executed by the loadlist
processor (permission bits = 700) has returned an entry
for the Define Device Area (DDA) that has an invalid
value in the length field. The length must be greater
than 0 and less than or equal to 2048 bytes. The loadlist
processor will continue processing after display the
error.
Action: See error 21 for recovery.
23
Execution of loaded program failed (non-fatal)
Cause: A module that has been executed by the loadlist
processor (permission bits = 700) has returned an error
code to the loadlist processor that indicates that
execution of the program failed. The loadlist processor
continues processing after displaying the error.
Action: If the VRM minidisk has been changed by
adding additional code, find the module that returned
the error and remove it.
24
No entry point was found.
Cause: The loadlist processor did not find any module
with entry point X' 1000'. This should be the VRM
nucleus module (permission bits = 450). This is the
module the loadlist processor passes control to and must
be present.
Action: If the VRM minidisk has been changed by
adding additional code, the VRM nucleus may have been
deleted or replaced. Make sure a module exists in the
loadlist that can receive control from the loadlist
processor, or install the original VRM again.