IBM RT PC Problem Determination Manual page 258

Hide thumbs Also See for RT PC:
Table of Contents

Advertisement

5-8 AIX Operating System Problem Determination Guide
10
Invalid device
Cause: The information contained in the POST Control
Block for the IPL device does not contain a valid value.
Since loadable POST routines that execute during IPL
have access to the POST Control Block, any of these
modules could have written the invalid value to this area
of the POST Control Block.
Action: If the VRM minidisk has been changed by
adding additional code, the invalid module must be
found and removed, or install the original VRM to
correct the problem.
11
Invalid index for address from inode.
Cause: This error may occur if the RT file system
contained on the VRM minidisk (or VRM diskette) has
been corrupted.
Action: If this error occurs when you IPL from the
VRM minidisk, install the VRM again. If this error
occurs when you IPL from diskette, use the backup
diskette to IPL.
Inode out of range.
12
Cause: See error 11 for cause and action.
13
Address out of range.
Cause: See error 11 for cause and action.