Technical data
PPU
Parameter
Input voltage
Power consumption, max.
Power loss
Heat dissipation
Degree of protection in acc. with EN 60529
Protection class in acc. with EN 61800-5-1
Pollution degree in acc. with EN 61800-5-1
Approvals
Classification:
Mounting position
Dimensions:
Weight, approx.
*)
See also
Further technical data for the PPU can be found in the following sections:
● Transport and Storage Conditions (Page 40)
● Operating Conditions (Page 41)
● Requirements for the power supply (Page 72)
Digital inputs/outputs:
● Technical data (Page 87)
PPU
Manual, 03/2013, 6FC5397-2DP40-3BA1
Operation
Transportation (in transportation
packaging)
Storage (in transport packaging)
Width
Height
Depth
with closed protective flap
Value
24 V DC + 20% / - 15%
60 W
28 W
Open-circuit ventilation
IP65 (front)
*)
IP20 (rear)
III (DVC A, PELV)
2
CE / cULus
3M1 in acc. with EN 60721-3-3
2M3 in acc. with EN 60721-3-2
1M2 in acc. with EN 60721-3-1
Vertical
PPU vertical:
310 mm
220 mm
105 mm
4.5 kg
8
PPU horizontal:
483 mm
220 mm
105 mm
221