Mounting an NX10.3 on an Active Line Module
Procedure:
1. Remove the spacers from the NX.
2. Position the NX on the left-hand side of the Line Module. The mounting fixtures fit exactly
3. Push the two units together.
4. Press down on the NX until it engages and is securely connected to the Line Module.
Dimension drawing
Figure 7-48
PPU
Manual, 03/2013, 6FC5397-2DP40-3BA1
in the five cutouts on the NX.
NX10.3 dimensions
Connectable components
7.7 NX10.3
207