X122 digital inputs/outputs
Connector designation:
Connector type:
Max. connectable cross-section:
Table 7- 84
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
An open input is interpreted as "low".
Note
Terminal M1 must be connected for the digital inputs (DI) 0 to 3 and 16/17 to function. This
can be done as follows:
 Connect the ground reference of the digital inputs.
 Jumper to terminal M: This removes the electrical isolation for these digital inputs.
PPU
Manual, 03/2013, 6FC5397-2DP40-3BA1
Pin assignment for X122
Signal name
Meaning
DI0
Digital input 0
DI1
Digital input 1
DI2
Digital input 2
DI3
Digital input 3
DI16
Digital input 16
DI17
Digital input 17
M1
Reference potential for terminals 1 to 6
M
Ground
DI/DO8
Digital input/output 8 (rapid input)
DI/DO9
Digital input/output 9 (rapid input)
M
Ground
DI/DO10
Digital input/output 10 (rapid input)
DI/DO11
Digital input/output 11 (rapid input)
M
Ground
X122
Spring-loaded terminal 1
0.5 mm
2
Connectable components